VMware Virtual Platform: HP ProLiant D元60 G6: Processor: Intel Xeon X7560 2.26 GHz 8 Processors, 128 Cores Intel Xeon E5645 2.40 GHz 2 Processors, 12 Cores, 24 Threads. Or if I am doing something wrong or forgetting something, please advise me also. VMware Virtual Platform HP ProLiant D元60 G6 Operating System: Ubuntu 18.04.5 LTS 5.4.0-52-generic x8664: Fedora 34 (Server Edition) Model: VMware, Inc. Set sata_args='sata_uid=1 sata_pcislot=5 synoboot_satadom=1 DiskIdxMap=0C SataPortMap=1 SasIdxMap=0'Īny tips would be welcome if anybody would have the same server running with the same P410 embedded controller and all 8 disks are recoginised and be able to work in RAID5 softraid. I guess that is by accident cause I don't know the exact settings of this line in grub.cfg :
#Hp dl360 g6 vmware bios settings install#
If I disable all controllers EXEPT the LSI1064, and connect 4 HD's to it (only has 1 SAS port) then I see the 4 drives and I can install the 6.2 patfile version 23739
![hp dl360 g6 vmware bios settings hp dl360 g6 vmware bios settings](https://helgeklein.com/wp-content/uploads/2013/05/iLO-Power-Settings.png)
Weve seen an advisory from HP that seems to outline a similar issue, but did not fix our. However, when i see in the compatible list of storage controllers, all the ones I have tried and tested with are suppose to work. Weve also tried some VMWare best-practices for BIOS config. Server boots with the stick but on all controllers listed above, when I connect the HD's it is not recognising any drives and I see the error in the webgui "Place hard drives" I do the adjustments in the grub.cfg file for SM, mac, VID, PID. (optional) 1 PCIE storage RAID controller with a LSI1068 chip with 2 SAS ports on PCI slot 6 (ALSO ONLY PLACEd FOR TESTING) But, we have a proper LSI controller and an external HP D2700 disk pack to offset the lack of internal bays. in HP ProLiant Servers to view, modify the BIOS / System settings such as. 1 PCI-E Storage RAID controller with a LSI1064 chip with 1 SAS port on PCI slot 3 (if I look in BIOS) THIS IS ONLY PLACED THERE FOR TESTING, I WOULD LIKE TO HAVE THE EMBEDDED P410 WORKING We have FreeNAS on a HP D元60 G5, a generation older than yours. HP 579229-001 PLATINUM POWER SUPPLY 1200W PROLIANT DL980 G7 DPS-1200FB-1 A. 1 Embedded Storage RAID controller P410 on the motherboard with 2 SAS ports 2 Embedded Storage controllers with each 4 ports SATA (not used for disks) 8x SAS 600Gb 15K disks in a backplane with 2 SAS cables HP Proliant M元50 G6 server with Xeon E5606, 36Gb RAM So I have some experience at this stage on how it all works. I have been successful for some years in setting up Supermicro servers with 1.03 and DS3615x in the past, all work fine, no problems in the setup, all drives detected and working. First of all, my detailed setup and explaining the problem. In my case it was RAID5:Īfter clicking on “Create Login Drive” my RAID was provisioned.I have a problem and after hours of trying to solve it myself I am posting this cause I am stuck. Then you need to select Smart Array P440ar controller as shown below: Select “Intelligent Provisioning” and press enter. RAID configuration tool is already built in the server.ĭuring the boot process, you need to enter the “Intelligent Provisioning” tool by pressing F10. You do not need to have any special CD to configure the RAID settings. server model and BIOS version HP ProLiant D元80 Gen9 BIOS: P89 Date. HP PADAB0G9VXC1CQ BIOS name and version Dell 0.3.37 HP P62 BIOS settings. log: A summary of Warning and Alert log messages. Setting up RAID 5 pretty straightforward on HP ProLiant D元80 server. Dell PowerEdge R720 server HP ProLiant D元80 G6 server VM 1 VM 2 VM 3 VM 4. New enterprise grade SSD disks are very safe.Out of 4 disks 1TB each, 3 TB is usable. When you implement the new HP D元80 Gen10 Server in our vSphere Environment it makes sense to take a closer look at the BIOS settings for better performance.After thinking about RAID 10 and RAID 5, I decided to go to RAID 5 as it provided the best cost-efficient solution in our case: 4 slots were occupied by disk, each one is 1TB SSD disk. The server comes as U1 standard factor with 8 slots for disks.
![hp dl360 g6 vmware bios settings hp dl360 g6 vmware bios settings](http://www.kozeniauskas.com/itblog/files/2011/01/ilo_uuid_2.jpg)
A few days ago I got a new toy ? It is a brand new HP ProLiant D元60 server with very impressive specs: